[KNOWLEDGE / FORMULAS]
Formula library and reference tables
Every formula and reference table used across the toolbox — so any result can be checked, explained and defended.
[01]
Mechanics & Power Transmission
Torque from power and speed
T = 9550 × P / n
T in N·m, P in kW, n in rpm. Multiply torque by speed to recover power.
Open calculatorGear ratio
i = N₂ / N₁
Output speed falls by the ratio, output torque rises by it (ideal).
Open calculatorOpen belt length
L = 2C + π(D + d)/2 + (D − d)²/(4C)
C is the centre distance between pulley centres.
Open calculatorBolt tightening torque
T = K × F × d
K is the nut factor, F the preload in newtons, d the nominal diameter in metres.
Open calculatorBearing rating life
L10 = (C/P)^p
Result in million revolutions. p = 3 for ball, 10/3 for roller bearings.
Open calculator[02]
Structural Analysis
Simply supported beam, UDL
M = wL²/8 · V = wL/2 · δ = 5wL⁴/(384EI)
Maximum moment and deflection at mid-span, maximum shear at the supports.
Open calculatorSimply supported beam, central point load
M = PL/4 · δ = PL³/(48EI)
Valid for a concentrated load acting at mid-span.
Open calculatorSection modulus
Z = I / y
y is the distance from the neutral axis to the extreme fibre.
Open calculatorRadius of gyration
r = √(I / A)
Used with effective length to get the slenderness ratio.
Open calculatorEuler buckling load
P(cr) = π²EI/(kL)²
k depends on end restraint: 1.0 pinned, 0.5 fixed, 2.0 cantilever.
Open calculatorBending stress
σ = M / Z
Compare against the section capacity φMs from AS 4100 for steel members.
Open calculator[03]
Steel & Fabrication
Mass of a steel section
m = A × L × ρ
A in m², L in m, ρ = 7850 kg/m³ for carbon steel.
Open calculatorSteel pipe mass per metre
m = π/4 × (D² − (D − 2t)²) × ρ
Based on outside diameter and wall thickness, not nominal bore.
Open calculatorFillet weld area
A = 0.5 × leg²
Throat thickness equals leg × cos 45°, about 0.707 × leg.
Open calculatorWeld heat input
HI = (V × I × 60)/(1000 × v) × η
v in mm/min, η the process thermal efficiency.
Open calculatorBend allowance
BA = θ × (R + K·T)
θ in radians. K factor is typically 0.33 for air-bent mild steel.
Open calculatorBolt circle coordinates
x = R cos(nθ) · y = R sin(nθ)
R is the pitch circle radius, θ the hole spacing angle.
Open calculator[04]
Civil & Earthworks
Reinforcement mass
m = d² / 162.2
Kilograms per metre for deformed bar of diameter d in millimetres.
Open calculatorTrench backfill
V(backfill) = V(trench) − V(pipe)
Deduct bedding and surround material separately where specified.
Open calculator[05]
Electrical
Three-phase apparent power
S = √3 × V × I
V is line-to-line voltage, I is line current, S in VA.
Open calculatorCable voltage drop
Vd = 2 × I × ρ × L / A
Use √3 instead of 2 for three-phase circuits. ρ ≈ 0.0225 for copper.
Open calculatorPower factor correction
kVAR = kW × (tan φ₁ − tan φ₂)
Size capacitor steps from the reactive power required.
Open calculator[R]
Reference tables
Material densities
| Material | Density (kg/m³) |
|---|---|
| Carbon steel | 7850 |
| Stainless steel | 7900 – 8100 |
| Cast iron | 7200 |
| Aluminium | 2700 |
| Copper | 8960 |
| Concrete (normal weight) | 2400 |
| Reinforced concrete | 2500 |
| Water (fresh) | 1000 |
| Seawater | 1025 |
| Hardwood (dressed) | 700 – 900 |
| Sand (dry) | 1600 |
| Crushed rock | 1500 – 1700 |
Common steel properties
| Property | Value |
|---|---|
| Modulus of elasticity, E | 200 GPa |
| Poisson ratio, ν | 0.30 |
| Density | 7850 kg/m³ |
| Coefficient of expansion, α | 12 × 10⁻⁶ / °C |
| Yield strength, grade 300 | 300 MPa |
| Yield strength, grade 350 | 350 MPa |
| Tensile strength, grade 8.8 bolt | 830 MPa |
| Tensile strength, grade 10.9 bolt | 1040 MPa |
Standard pipe nominal bore
| Nominal bore | Outside diameter (mm) |
|---|---|
| DN 15 (½") | 21.3 |
| DN 20 (¾") | 26.7 |
| DN 25 (1") | 33.4 |
| DN 40 (1½") | 48.3 |
| DN 50 (2") | 60.3 |
| DN 80 (3") | 88.9 |
| DN 100 (4") | 114.3 |
| DN 150 (6") | 168.3 |
| DN 200 (8") | 219.1 |
| DN 250 (10") | 273.0 |
| DN 300 (12") | 323.9 |
Typical service temperatures & limits
| Item | Typical value |
|---|---|
| Max. velocity, pump suction line | 1.5 m/s |
| Max. velocity, pump discharge line | 3.0 m/s |
| Max. velocity, gravity drain | 1.0 m/s |
| Tank freeboard allowance | 10 – 15% |
| Voltage drop limit, installations | 5% |
| Minimum pavement drainage grade | 1.0% |
| Concrete cover, slab on ground | 30 mm |
| Nominal mix dry volume factor | 1.54 |
Unit conversion reference
Every conversion factor in the toolbox is available in the conversion tools, from millimetres to kips, litres to oil barrels and newtons per square millimetre to megapascals.