Introduction
Heat input is the energy delivered per millimetre of weld. Too low, and thick sections quench too fast, hardness rises and hydrogen cracking becomes likely. Too high, and toughness in the heat-affected zone falls while distortion grows.
It links directly to the weld procedure: voltage, current and travel speed are not preferences, they are the variables that determine whether the procedure reproduces the tested result.
Calculating heat input
Heat input in kilojoules per millimetre equals voltage times current times 60, divided by travel speed in millimetres per minute and 1 000. A typical manual metal arc pass at 26 V and 220 A travelling at 240 mm/min gives 1.43 kJ/mm.
Note the travel speed unit: millimetres per minute. Using millimetres per second inflates the answer by a factor of 60 and is the most common error in weld documentation.
Preheat and interpass temperature
Preheat slows cooling, allowing hydrogen to escape and reducing the risk of cracking in thick sections, high-carbon-equivalent steels and low ambient temperatures. Interpass temperature caps the other end — too hot a joint loses toughness in the heat-affected zone.
AS/NZS 1554.1 sets requirements by material thickness and grade, and the weld procedure must record them. Preheat measured with a contact thermometer at the joint, not guessed from the weather, is what makes the record meaningful.
Distortion is shrinkage you did not plan for
Weld metal contracts as it cools. Because the contraction is restrained by the surrounding steel, it shows up as angular distortion, bowing or longitudinal shrinkage — typically a few millimetres per metre for heavily welded sections.
Control measures follow the mechanism: balance welding about the neutral axis, back-step, use the minimum practical weld size, allow the part to move freely, and sequence so the last welds close the job rather than pull it out of square.
- Weld from the centre outwards on long seams.
- Balance opposite sides rather than completing one side first.
- Use jigs and strongbacks where dimensions are critical, then remove them progressively.
- Allow a shrink allowance in the cutting list for heavily welded assemblies.
[F]Technical formulas
Heat input
HI = (V × A × 60) / (1 000 × v)
v in mm/min, result in kJ/mm.
Heat input per pass (total)
HI(total) = Σ HI(passes)
Compare with the procedure’s limit.
Carbon equivalent (CE)
CE = C + Mn/6 + (Cr + Mo + V)/5 + (Ni + Cu)/15
Weldability indicator for carbon-manganese steels.
[V]Explanation of variables
| Symbol | Meaning | Unit |
|---|---|---|
| V | Arc voltage | V |
| A | Welding current | A |
| v | Travel speed | mm/min |
| HI | Heat input | kJ/mm |
[E]Worked example
Heat input for a 220 A pass
- 01Voltage 26 V, current 220 A, travel speed 240 mm/min.
- 02Arc power = 26 × 220 = 5 720 W.
- 03Energy per millimetre = 5 720 / (240/60) = 5 720 / 4 = 1 430 J/mm.
- 04HI = 1.43 kJ/mm — within a typical 1.0 to 2.5 kJ/mm range for structural fillet work.
Result
If the welder slows to 120 mm/min, heat input doubles to 2.86 kJ/mm and the procedure is no longer the one that was qualified.
[A]Practical applications
- Writing and checking weld procedure specifications.
- Investigating cracking in thick-section or low-temperature work.
- Planning a weld sequence to keep a frame within tolerance.
- Recording compliance on a job that specifies maximum heat input.
[!]Common mistakes
- Using travel speed in mm/s instead of mm/min.
- Treating preheat as a workshop preference rather than a procedure variable.
- Allowing interpass temperature to climb unchecked on multi-pass welds.
- Correcting distortion by welding on the opposite side after the fact — it adds residual stress instead of removing it.
[S]References and sources
- AS/NZS 1554.1 – Structural steel welding: welding of steel structuresPreheat, interpass and heat input requirements.
- AS/NZS ISO 3834 series – Quality requirements for fusion weldingProcedure qualification and documentation.
Standards are cited by designation and title only — no clause text is reproduced. Purchase current editions from Standards Australia, and confirm the edition that applies to your project.