Hemispherical Tank Head Volume Calculator
A hemispherical head is half a sphere. Enter the inside diameter, the straight flange and how many heads you need.
Dimensions & liquid
Dimensions measured
Liquid
Reference density at 4 °C. Leave the density blank to use it.
Dimensions used · internal
- Inside diameter
- 1,000 mm
- Straight flange
- 25 mm
- Heads
- 1
- Dished depth
- 500 mm
SCHEMATIC · DISHED HEAD PROFILE
Head volume
281L
0.281 m³
- Geometric total capacity
- 281 L0.281 m³
- Working capacity
- 281 Lall heads
- Remaining capacity
- 0 L0.000 m³
- Liquid weight
- 281 kg0.28 t
- Liquid
- Water (fresh) · 1,000 kg/m³
| Unit | Volume | Total |
|---|---|---|
| Litres | 281 | 281 |
| Cubic metres | 0.281 | 0.281 |
| US gallons | 74 | 74 |
| Imperial gallons | 62 | 62 |
These are geometric volumes. Usable capacity is smaller once freeboard, the outlet height above the floor and internal fittings are deducted.
Formulas used
- Dished volume Vd = π/12 × D³
- Flange volume Vf = π/4 × D² × SF
- Head volume V = Vd + Vf (per head)
- Depth of the dish = D ÷ 2
This calculation, step by step
- 1Dished volume per headπ/12 = 0.2618 × 1.000³ = 0.262 m³
- 2Straight flange volumeπ/4 × 1.000² × 0.025 = 0.020 m³
- 3Volume per head0.262 + 0.020 = 0.281 m³
- 4Volume of 1 head0.281 × 1 = 0.281 m³
- 5Liquid weight0.281 m³ × 1,000 kg/m³ = 281 kg
Worked example
- Head: inside diameter 1,200 mm with a 25 mm straight flange.
- Dished volume = π/12 × 1.2³ = 0.452 m³ (452 L).
- Flange volume = π/4 × 1.2² × 0.025 = 0.028 m³ (28 L).
- One head holds 0.481 m³ (481 L); a vessel with two heads adds 962 L.
Assumptions & limits
- Inside diameter and inside dished depth are used; no corrosion allowance is added.
- The head is a true hemisphere with a cylindrical straight flange.
- Head volume is capacity, not usable storage once nozzles and the shell are considered.
A hemispherical head holds twice the volume of a 2:1 elliptical head of the same diameter.
1,200 mm diameter holds about 452 litres dished, plus the flange.
Forming thins the crown, so fabricators check minimum thickness after forming.
TOTAL VS WORKING
Two numbers, two different jobs
The total capacity tells you what the shell holds when it is full. The working capacity at the level you entered is what the vessel is actually holding now — use that one for dosing, pump run times, transfer volumes and remaining ullage.
ALL TANK CALCULATORS
Compare every tank shape
Vertical, horizontal, rectangular, conical, cone bottom and dished heads — all on one page.
FABRICATION AND PROJECTS
From the volume to the fabricated tank
Capacity and level figures feed straight into shell design, nozzle schedules, bunding and freight planning. These resources cover the fabrication and project side of the same work.