[TANK VOLUME CALCULATORS]

Hemispherical Tank Head Volume Calculator

A hemispherical head is half a sphere. Enter the inside diameter, the straight flange and how many heads you need.

Dimensions & liquid

Dimensions measured

mm
mm

Liquid

kg/m³

Reference density at 4 °C. Leave the density blank to use it.

Dimensions used · internal

Inside diameter
1,000 mm
Straight flange
25 mm
Heads
1
Dished depth
500 mm
Ø 1,000depth 86SF 25

SCHEMATIC · DISHED HEAD PROFILE

Head volume

281L

0.281 m³

Geometric total capacity
281 L0.281 m³
Working capacity
281 Lall heads
Remaining capacity
0 L0.000 m³
Liquid weight
281 kg0.28 t
Liquid
Water (fresh) · 1,000 kg/m³
UnitVolumeTotal
Litres281281
Cubic metres0.2810.281
US gallons7474
Imperial gallons6262

These are geometric volumes. Usable capacity is smaller once freeboard, the outlet height above the floor and internal fittings are deducted.

Formulas used

  • Dished volume Vd = π/12 × D³
  • Flange volume Vf = π/4 × D² × SF
  • Head volume V = Vd + Vf (per head)
  • Depth of the dish = D ÷ 2

This calculation, step by step

  1. 1Dished volume per headπ/12 = 0.2618 × 1.000³ = 0.262 m³
  2. 2Straight flange volumeπ/4 × 1.000² × 0.025 = 0.020 m³
  3. 3Volume per head0.262 + 0.020 = 0.281 m³
  4. 4Volume of 1 head0.281 × 1 = 0.281 m³
  5. 5Liquid weight0.281 m³ × 1,000 kg/m³ = 281 kg

Worked example

  • Head: inside diameter 1,200 mm with a 25 mm straight flange.
  • Dished volume = π/12 × 1.2³ = 0.452 m³ (452 L).
  • Flange volume = π/4 × 1.2² × 0.025 = 0.028 m³ (28 L).
  • One head holds 0.481 m³ (481 L); a vessel with two heads adds 962 L.

Assumptions & limits

  • Inside diameter and inside dished depth are used; no corrosion allowance is added.
  • The head is a true hemisphere with a cylindrical straight flange.
  • Head volume is capacity, not usable storage once nozzles and the shell are considered.

A hemispherical head holds twice the volume of a 2:1 elliptical head of the same diameter.

1,200 mm diameter holds about 452 litres dished, plus the flange.

Forming thins the crown, so fabricators check minimum thickness after forming.

TOTAL VS WORKING

Two numbers, two different jobs

The total capacity tells you what the shell holds when it is full. The working capacity at the level you entered is what the vessel is actually holding now — use that one for dosing, pump run times, transfer volumes and remaining ullage.