[STRUCTURAL]

Basic Load & Load Combination Calculator

Area loads to line load, and the AS 1170 ultimate combination.

Inputs
kPa
kPa
m
m

Results update as you type. All calculations run in your browser — nothing is uploaded.

Calculated result

Ultimate line load w*

29.70kN/m
Service line load22.50kN/m
Ultimate end reaction89.10kN
Ultimate moment (w*L²/8)133.6kN·m
Total ultimate load178.2kN

About this calculator

Convert dead and live area loads into a line load on a beam using its tributary width, then apply the common ultimate combination 1.2G + 1.5Q to get the design load for member sizing.

What you enter

Dead load G in kPa; Live (imposed) load Q in kPa; Tributary width in m; Span in m. Every result is recalculated in the browser as you type.

Also searched as

  • load
  • dead load
  • live load
  • combination
  • tributary
  • as 1170
  • kn/m

One of the structural engineering tools on Engineering Toolbox Australia. Inputs and results use Australian metric units with imperial equivalents where noted.

Frequently asked questions

Convert dead and live area loads into a line load on a beam using its tributary width, then apply the common ultimate combination 1.2G + 1.5Q to get the design load for member sizing. With the default inputs it reports ultimate line load w* in kN/m, service line load in kN/m, ultimate end reaction in kN.

Results are for preliminary estimating and study. Verify against the applicable Australian Standard and have final designs certified by a suitably qualified engineer.