[PIPING ENGINEERING]

Thermal Expansion and Pipe Support Spacing

How much a steel line grows per degree, where that movement goes, and how support spacing is chosen so the pipe does not sag between supports.

5 MIN READ3 SECTIONS

Introduction

Carbon steel expands about 12 micrometres per metre per degree Celsius. On a 30 m line rising 60 °C, that is 21.6 mm of movement — small in absolute terms, but more than enough to shear a connection or lift a support if the line is fully restrained.

Expansion is managed by allowing movement, not by adding more steel. Loops, offsets, guides and anchors all exist to decide where the movement goes.

Calculating the movement

Free expansion is the coefficient of thermal expansion multiplied by length and temperature change. For carbon steel with α ≈ 12 × 10⁻⁶ per °C, the result is roughly 1.2 mm per metre per 100 °C.

Stainless steels are higher, around 16 to 17 × 10⁻⁶ per °C, which is why stainless lines need more allowance than a carbon steel line of the same length.

Where the movement is absorbed

An expansion loop converts axial growth into bending of the loop legs. The loop needs length in both directions, and the pipe must be guided so the movement enters the loop rather than pushing a branch connection sideways.

Anchors divide a run into independently moving sections. Guides keep the line straight so it does not buckle. Restraints must be designed for the forces the restrained expansion generates, which can be large.

Support spacing

Support spacing is set by allowable sag between supports, plus the loads from valves, insulation and water in test. AS 4041 and project specifications give spacing tables by bore and service.

Spacing also affects expansion: fewer supports mean longer free spans between guides, and a line that can move more than intended.

  • Spacing decreases as bore decreases — small lines sag more easily.
  • Valves, flanges and heavy fittings need a support close by.
  • Allow for hydrostatic test water mass when checking supports.
  • Spring supports are used where a support cannot be allowed to unload as the line grows.

[F]Technical formulas

Free thermal expansion

ΔL = α × L × ΔT

α in per °C, L in mm, gives ΔL in mm.

Expansion per metre

ΔL/m = α × ΔT × 1 000

Carbon steel: ≈ 1.2 mm per metre per 100 °C.

[V]Explanation of variables

SymbolMeaningUnit
ΔLFree expansionmm
αCoefficient of linear expansionper °C (12 × 10⁻⁶ carbon steel)
LLength of runmm
ΔTTemperature change from installation°C

[E]Worked example

A 30 m carbon steel line warming 60 °C

  1. 01α = 12 × 10⁻⁶ per °C, L = 30 000 mm, ΔT = 60 °C.
  2. 02ΔL = 12 × 10⁻⁶ × 30 000 × 60 = 21.6 mm.
  3. 03If both ends are anchored, that 21.6 mm becomes strain in the pipe and force at the anchors.
  4. 04Provide a loop or offset with enough leg length to absorb 21.6 mm without overstressing the pipe.

Result

Every 30 m of that line needs 21.6 mm of movement allowance — about the thickness of a finger, and enough to break a rigid connection.

[A]Practical applications

  • Laying out a steam or hot water line.
  • Checking whether a proposed anchor position is workable.
  • Setting support spacing for a long small-bore run.
  • Investigating a leak at a branch connection on a hot line.

[!]Common mistakes

  • Treating a line as rigid and anchoring both ends without an expansion check.
  • Forgetting that the installation temperature is not always the cold condition.
  • Using the carbon steel expansion coefficient for stainless or copper.
  • Adding supports without considering how they affect guided movement.

[S]References and sources

  • AS 4041 – Pressure pipingDesign of piping systems including support and flexibility requirements.
  • AS 2885.1 – Pipelines: design and constructionPipeline design requirements where applicable.

Standards are cited by designation and title only — no clause text is reproduced. Purchase current editions from Standards Australia, and confirm the edition that applies to your project.