Introduction
Pipe size is chosen from flow rate and an acceptable velocity, then checked for pressure drop. Velocity is the practical control: too low and solids settle or cost is wasted on oversized pipe; too high and pressure drop, noise, erosion and water hammer all rise together.
Velocity scales with the square of diameter, so a modest increase in bore produces a large reduction in velocity and a much larger reduction in friction loss.
Velocity from flow and bore
Velocity is flow rate divided by internal flow area. For water at 20 L/s through a DN100 pipe with 102.3 mm bore, the area is 8 217 mm², and velocity works out at 2.43 m/s.
Note that the bore, not the nominal size, must be used. DN100 pipe in different schedules has different wall thickness and therefore a different bore — the difference matters at these velocities.
Typical velocity ranges
For clean water in continuous duty, general practice sits between about 1.0 and 2.5 m/s, with suction lines kept lower to protect pump NPSH. Services carrying solids or slurries run lower to avoid settling, while some high-pressure systems run higher to control cost.
These ranges are industry practice, not universal rules. The governing requirement is usually pressure drop, erosion allowance or noise, and those come from the project specification.
- Pump suction: keep low, typically 1.0 to 1.5 m/s, to limit NPSH loss.
- Pump discharge and general transfer: 1.5 to 2.5 m/s.
- Long mains: lower velocity reduces pumping energy over life.
- Slurries and solids-bearing services: lower again, above the settling velocity.
Pressure drop follows velocity squared
Friction loss is proportional to velocity squared for a given pipe. Halving velocity by doubling area can cut friction loss by roughly 75 %, at the cost of a larger pipe — which is why life-cycle pumping cost is worth checking on long runs.
[F]Technical formulas
Velocity
v = Q / A
Q in m³/s, A in m²; A = πd²/4 with d in metres.
Area from bore
A = π × d² / 4
d is internal diameter.
Flow from velocity
Q = v × A
Gives m³/s; multiply by 1 000 for L/s.
[V]Explanation of variables
| Symbol | Meaning | Unit |
|---|---|---|
| Q | Volumetric flow rate | m³/s |
| A | Internal flow area | m² |
| v | Mean velocity | m/s |
| d | Internal diameter (bore) | m |
[E]Worked example
20 L/s through DN100
- 01Bore 102.3 mm = 0.1023 m. Area = π × 0.1023²/4 = 0.008217 m².
- 02v = 0.020 / 0.008217 = 2.43 m/s — high for continuous duty.
- 03Try DN125, bore 128.2 mm: area = 0.01291 m², v = 1.55 m/s.
- 04Friction loss falls roughly by the ratio of velocities squared, about 0.41 times the DN100 value.
Result
One nominal size up drops velocity from 2.43 to 1.55 m/s and cuts friction loss by about 60 %.
[A]Practical applications
- Selecting a line size for a transfer duty.
- Checking an existing line before increasing pump flow.
- Estimating whether noise or erosion is likely at a proposed duty.
- Comparing capital cost against pumping cost on a long main.
[!]Common mistakes
- Using nominal bore instead of internal diameter.
- Ignoring velocity on the suction side of a pump.
- Assuming doubling the bore halves the velocity — it quarters it.
- Sizing on velocity alone without checking pressure drop and available head.
[S]References and sources
- AS 4041 – Pressure pipingDesign requirements for pressure piping systems.
- AS 2885 series – Pipelines: gas and liquid petroleumPipeline design where the AS 2885 series applies.
Standards are cited by designation and title only — no clause text is reproduced. Purchase current editions from Standards Australia, and confirm the edition that applies to your project.
FABRICATION AND PROJECTS
Turning the take-off into a fabrication package
Mass, surface area and cutting figures become the material list a fabricator prices from. These resources cover fabrication capability and where the projects are.