[STORAGE TANKS]

Tank Capacity and Partial Fill Volumes

Volume formulas for vertical, rectangular, horizontal and cone-bottom tanks, plus how to read a level and get litres rather than cubic metres.

5 MIN READ3 SECTIONSIncludes diagram

Introduction

Tank volume looks like the simplest calculation on any site until the tank is horizontal, or has a dished end, or someone asks how much is in it at 800 mm on the dip tape.

The geometry for each case differs, but the principle does not: find the wetted cross-sectional area, multiply by the length or height, and convert to litres.

HhV = πr²h, mass = V × density
Vertical cylindrical tank with liquid level h

Full capacity

A vertical cylinder holds πr²h. A rectangular tank holds L × W × H. A cone-bottom tank adds a cone of volume πr²h/3 below the cylindrical section.

Convert cubic metres to litres by multiplying by 1 000. A 2.4 m diameter tank with 3 m of shell holds π × 1.2² × 3 = 13.57 m³, or 13 571 L.

Partial fill in a horizontal cylinder

The wetted area of a partially filled horizontal cylinder is a circular segment: the area bounded by a chord at the liquid surface. It requires the segment area formula, not a simple proportion of diameter.

This is why a dipstick reading half the diameter does not indicate half the volume — the tank is wider at mid-height, so the level rises more slowly around the middle than near the bottom.

Freeboard and working capacity

Nominal capacity is not working capacity. Freeboard, the ullage space left for thermal expansion, filling surges and foam, reduces the usable volume. Tank standards and site requirements set the freeboard; it must not be treated as available capacity in an operating procedure.

For fuel and chemical storage, the bund and the tank are designed together — a full tank plus a fire hose stream is the case that actually sizes the bund.

[F]Technical formulas

Vertical cylinder

V = π × r² × h

Multiply m³ by 1 000 for litres.

Rectangular tank

V = L × W × H

Use internal dimensions.

Cone bottom

V(cone) = π × r² × h / 3

Add to the cylindrical volume.

Horizontal segment area

A = r² × (θ − sin θ)/2

θ in radians; segment for the wetted part.

[V]Explanation of variables

SymbolMeaningUnit
rInternal radiusm
hLiquid depth or shell heightm
LTank lengthm
θSegment half-angle in radiansrad

[E]Worked example

Capacity of a vertical tank

  1. 01Internal diameter 2.4 m, so r = 1.2 m; straight shell 3.0 m high.
  2. 02Cylinder volume = π × 1.2² × 3.0 = 13.57 m³.
  3. 03Convert: 13.57 × 1 000 = 13 571 L.
  4. 04With 200 mm of freeboard, working capacity is about π × 1.44 × 2.8 = 12.67 m³, or 12 670 L.

Result

Nominal 13 571 L, working 12 670 L. The difference is 900 L that an operating procedure must not promise.

[A]Practical applications

  • Sizing a water or process tank from a daily demand.
  • Producing a dip chart for a horizontal fuel tank.
  • Estimating liquid mass for a structural support check.
  • Checking a supplier’s stated capacity against the geometry.

[!]Common mistakes

  • Using outside dimensions and overstating capacity.
  • Assuming level is proportional to volume in a horizontal tank.
  • Ignoring dished ends or a cone bottom in the total.
  • Treating nominal capacity as usable capacity.

[S]References and sources

  • AS 1692 – Tanks for flammable and combustible liquidsConstruction and marking requirements for fuel tanks.
  • AS 2304 – Water tanks for fire safetyRequirements where stored water serves fire protection.

Standards are cited by designation and title only — no clause text is reproduced. Purchase current editions from Standards Australia, and confirm the edition that applies to your project.

FABRICATION AND PROJECTS

From the volume to the fabricated tank

Capacity and level figures feed straight into shell design, nozzle schedules, bunding and freight planning. These resources cover the fabrication and project side of the same work.